System Requirements
Veeam Backup & Replication provides different types of snapshot integrations and these integrations support different storage systems:
- NAS integration with built-in storage systems
- VMware and Veeam Agent Integrations with built-in storage systems
VMware and Veeam Agent Integrations with Universal Storage API integrated systems
NOTE |
[For VMware integration] You may encounter scenarios when Veeam Backup & Replication and the storage system support different versions of the virtual platform. In such cases, we recommend using versions supported by the storage system. If other versions are used, Veeam support will assist only with issues unrelated to version compatibility. |
NAS integration is possible with the following built-in storage systems.
Dell PowerScale (formerly Isilon)
- Filer integration for NAS backup functionality
- NFS or SMB (CIFS) connectivity
- OneFS 8.1.2 to 9.9
- NFS or SMB (CIFS) connectivity
- ONTAP 7-mode versions 8.2 up to 8.2.5
- ONTAP cluster-mode versions 9.1 to 9.15.1
- NFS, Fibre Channel or iSCSI connectivity
- ONTAP 7-mode versions 8.2 up to 8.2.5
- ONTAP cluster-mode versions 9.1 to 9.15.1
Lenovo ThinkSystem DM/DG Series
- NFS or SMB (CIFS) connectivity
- ONTAP 7-mode versions 8.2 up to 8.2.5
- ONTAP cluster-mode versions 9.1 to 9.15.1
NetApp ONTAP FAS/AFF/ASA, FlexArray (V-Series), Edge/Select/Cloud VSA
- NFS or SMB (CIFS) connectivity
- ONTAP 7-mode versions 8.2 up to 8.2.5
- ONTAP cluster-mode versions 9.1 to 9.15.1
- Filer integration for NAS backup functionality
- NFS or SMB (CIFS) connectivity
- Nutanix File Server 3.8.1.3 to 5.0
VMware and Veeam Agent Integrations with Built-in Storage Systems
VMware and Veeam Agent integrations are possible with the following built-in storage systems.
- VMware integration only
- NFS connectivity only
- HyperFlex 4.0(2x) or later (Backup from Storage Snapshots, Full Integration mode)
- Basic authentication is not supported for SSO users in HyperFlex
Dell VNX, VNX2, VNXe and Unity XT, Unity
- NFS, Fibre Channel (FC) or iSCSI connectivity
- Dell VNX/VNX2 all OE versions are supported
- Dell VNXe OE versions 3.x
- Dell Unity XT/Unity OE versions 5.0 to 5.4
- NFS, Fibre Channel or iSCSI connectivity
- ONTAP 7-mode versions 8.2 up to 8.2.5
- ONTAP cluster-mode versions 9.1 to 9.15.1
- Fibre Channel (FC) or iSCSI connectivity
- 3PAR OS versions 3.2.2 up to 3.3.2
- WSAPI 1.5 and later
- iSCSI VLAN tags are supported
- Fibre Channel (FC) or iSCSI (starting from OS versions 4.3 or later) connectivity
- OS versions 4.x
- Fibre Channel (FC) or iSCSI connectivity
- OS version 9.3 or later
- Fibre Channel (FC) or iSCSI connectivity
iSCSI is supported starting from OS version 10.3.
- OS version 10.2 or later
HPE Nimble Storage AF-Series, HF-Series and CS-Series
- Fibre Channel (FC) or iSCSI connectivity
- Nimble OS 5.0 and later
- Fibre Channel (FC) or iSCSI connectivity
- OS version 6.1
HPE StoreVirtual (formerly LeftHand/P4000 Series) and StoreVirtual VSA
- iSCSI connectivity only
- LeftHand OS versions 9.5 up to 12.8
- HPE SV3200 (LeftHand OS version 13) is not supported
- NFS, Fibre Channel or iSCSI connectivity
- ONTAP 7-mode versions 8.2 up to 8.2.5
- ONTAP cluster-mode versions 9.1 to 9.15.1
Lenovo ThinkSystem DM/DG Series
- NFS, Fibre Channel or iSCSI connectivity
- ONTAP 7-mode versions 8.2 up to 8.2.5
- ONTAP cluster-mode versions 9.1 to 9.15.1
NetApp ONTAP FAS/AFF/ASA, FlexArray (V-Series), Edge/Select/Cloud VSA
- NFS, Fibre Channel or iSCSI connectivity
- ONTAP 7-mode versions 8.2 up to 8.2.5
- ONTAP cluster-mode versions 9.1 to 9.15.1
VMware and Veeam Agent Integrations with Universal Storage API Integrated Systems
To start working with Universal Storage API integrated systems, you must install storage system plug-ins. VMware and Veeam Agent integrations are possible with the following storage systems.
- Fibre Channel (FC) or iSCSI connectivity
- DataCore SANsymphony 10.0 PSP12 or later
- Fibre Channel (FC) or iSCSI connectivity
- Dell PowerMax/VMAX All Flash (PowerMax OS microcode family 5978 or later)
- Unisphere for PowerMax 9.2.1.6 or later
- Fibre Channel (FC) or iSCSI connectivity
- Dell PowerStore (PowerStore OS 3.0 or later)
Dell SC Series (formerly Compellent)
- Fibre Channel (FC) or iSCSI connectivity
- Storage Center OS 7.4.2 or later
- FluidFS volumes and Live Volumes are not supported
Fujitsu ETERNUS AF and DX Series
- Fibre Channel (FC) or iSCSI connectivity
- ETERNUS AF series: AF250 S2, AF650 S2, AF150 S3, AF250 S3, AF650 S3
- ETERNUS DX series: DX60 S4, DX100 S4, DX200 S4, DX500 S4, DX600 S4, DX8900 S4, DX60 S5, DX100 S5, DX200 S5, DX500 S5, DX600 S5, DX900 S5, DX600 S6, DX900 S6, DX8900 S6
- Storage firmware version:
- ETERNUS AF S2 and DX S4 series (except DX8900 S4): V10L88-1000 or later
- ETERNUS AF S3 and DX S5 series, DX8900 S4: V11L30-5000 or later
- ETERNUS DX S6 series: V12L10-0000 or later
- Fibre Channel (FC) or iSCSI connectivity
- VSP E series (93-03-01-60/00 or later)
- VSP F series (88-07-01-x0/00 or later)
- VSP G series (88-07-01-x0/00 or later)
- VSP 5100 and VSP 5500 (90-05-01-00/00 or later)
- VSP 5200 and VSP 5600 (90-08-01-00/00 or later)
- Fibre Channel (FC) or iSCSI connectivity
- HPE XP8 (90-05-01-00/00 or later)
IBM FlashSystem (formerly Spectrum Virtualize, includes IBM StorWize and IBM SVC)
- Fibre Channel (FC) or iSCSI connectivity
- IBM Spectrum Virtualize OS version 8.2 or later
- Policy-based replication is not supported
- NFS, Fibre Channel (FC) or iSCSI connectivity
- InfiniBox 5.0 or later
Note |
You must add to the backup infrastructure only one of the two InfiniBox storage arrays for which Active/Active Replication is configured, or exclude the replicating volumes on one of these arrays from rescan. For details on how to exclude volumes from rescan, see Rescanning Storage Systems. |
- Fibre Channel (FC) or iSCSI connectivity
- M120, M320, M320F, M520, M720, M720F (Storage Control Software revision 1234 or later)
- Fibre Channel (FC) or iSCSI connectivity
- V100, V300 (93-04-21-XX or later), V10e (88-08-09-XX or later)
- iSCSI connectivity
- Element OS version 10.0 or later
- Fibre Channel (FC) or iSCSI connectivity
- Purity 4.10 or later
Tintri IntelliFlash (formerly Western Digital IntelliFlash, Tegile)
- NFS, Fibre Channel (FC) or iSCSI connectivity
- Tintri IntelliFlash 3.11 or later