New-VBRFileRestoreLinuxHelperApplianceOptions

Short Description

Defines configuration settings for a temporary helper appliance.

Applies to

Product Edition: Standard, Enterprise, Enterprise Plus, Veeam Universal License

Syntax

New-VBRFileRestoreLinuxHelperApplianceOptions -Server <CHost> [-ResourcePool <CViResourcePoolItem>] [-NetworkInfo <IVBRServerNetworkInfo>] [-IP <IPAddress>] [-NetworkMask <String>] [-Gateway <IPAddress>] [-PreferredDNSServer <IPAddress>] [-AlternateDNSServer <IPAddress>] [-IPv6 <IPAddress>] [-IPv6PrefixLength <Int32>] [-IPv6Gateway <IPAddress>] [-IPv6PreferredDNSServer <IPAddress>] [-IPv6AlternateDNSServer <IPAddress>] [-FromNSS] [-EnableFTP]  [<CommonParameters>]

Detailed Description

This cmdlet defines configuration settings for a temporary helper appliance.

Parameters

Parameter

Description

Type

Required

Position

Accept
Pipeline
Input

Server

Specifies the ESXi host on which the temporary helper appliance must be registered.

Note: If you specify a host for the Novell file system proxy appliance, make sure that it allows running VMs with 64-bit guest OSes.

Accepts the CHost object. To get this object, run the Get-VBRServer cmdlet.

True

Named

True (ByPropertyName)

ResourcePool

Specifies the resource pool to which the helper appliance must be placed.

Accepts the CViResourcePoolItem object. To get this object, run the Find-VBRViResourcePool cmdlet.

False

Named

True (ByPropertyName)

NetworkInfo

Specifies the network settings for the helper appliance.

Note:

  • The helper appliance must be placed in the same network where the backup server resides.
  • If you do not provide this parameter, the cmdlet will apply the VM network settings for the helper appliance.

Accepts the IVBRServerNetworkInfo[] object. To get this object, run the Get-VBRViServerNetworkInfo cmdlet.

False

Named

False

IP

Specifies the IPv4 address that you want to assign to the helper appliance.

Note: The helper appliance must be placed in the same network where the backup server resides.

IPAddress

False

Named

False

NetworkMask

For the IP parameter specified.

Specifies the network mask that you want to assign to the helper appliance.

Note: The helper appliance must be placed in the same network where the backup server resides.

String

False

Named

False

Gateway

Specifies the IPv4 address of the DNS server in the network where the helper appliance resides.

IPAddress

False

Named

False

PreferredDNSServer

Specifies the IPv4 address of the alternate DNS server in the network where the helper appliance resides.

IPAddress

False

Named

False

AlternateDNSServer

Specifies the IPv4 address of the alternate DNS server in the network where the helper appliance resides.

IPAddress

False

Named

False

IPv6

Specifies the IPv6 address that you want to assign to the helper appliance.

Note: The helper appliance must be placed in the same network where the backup server resides.

IPAddress

False

Named

False

IPv6PrefixLength

For the IPv6 addresses specified.

Specifies the length of the IPv6 prefix.

Int32

False

Named

False

IPv6Gateway

Specifies the IPv6 address of the default gateway in the network where the appliance resides.

IPAddress

False

Named

False

IPv6PreferredDNSServer

Specifies the IPv6 address of the DNS server in the network where the helper appliance resides.

IPAddress

False

Named

False

IPv6AlternateDNSServer

Specifies the IPv6 address of the alternate DNS server in the network where the appliance resides.

IPAddress

False

Named

False

FromNSS

Defines that the cmdlet will deploy a specific appliance that supports the Novell Storage Services file system.

Default: False.

SwitchParameter

False

Named

False

EnableFTP

Enables the FTP access to the restored file system.

If you provide this parameter, users will be able to access the helper appliance over FTP, browse the file system of the restored VM and download necessary files on their own.

Default: False.

SwitchParameter

False

Named

False

<CommonParameters>

This cmdlet supports Microsoft PowerShell common parameters. For more information on common parameters, see Microsoft Docs.

Output Object

The cmdlet returns the VBRFileRestoreLinuxHelperApplianceOptions object that defines settings for a temporary helper appliance.

Examples

Defining Temporary Helper Appliance for File Restore from CDP Replica

This example shows how to define settings for a temporary helper appliance for file restore from a CDP replica. The helper appliance will be deployed on the ESXi01 ESXi host in the Servers resource pool.

$server = Get-VBRServer -Name "ESXi01"

$resoursepool = Find-VBRViResourcePool -Server $server -Name "Servers"

$helper = New-VBRFileRestoreLinuxHelperApplianceOptions -Server $server -ResourcePool $resoursepool

Perform the following steps:

  1. Run the Get-VBRServer cmdlet. Specify the Name parameter value. Save the result to the $server variable.
  2. Run the Find-VBRViResourcePool cmdlet. Set the $server variable as the Server parameter value. Specify the Name parameter value. Save the result to the $resoursepool variable.
  3. Run the New-VBRFileRestoreLinuxHelperApplianceOptions cmdlet. Set the $server variable as the Server parameter value. Set the $resoursepool variable as the ResourcePool parameter value. Save the result to the $helper variable.