Set-NimbleHost
Short Description
Modifies settings of HPE Nimble storage systems.
Applies to
Platform: VMware
Product Edition: Standard, Enterprise, Enterprise Plus, Veeam Universal License
Syntax
Set-NimbleHost -Host <CNimbleHost> [-Description <string>] [-UserName <string>] [-Password <string>] [-Credentials <CInternalCredentials>] [-Proxy <IProxy[]>] [-MountServer <CHost>] [-VolumeScanType {All | Exclude | Include}] [-IncludedVolume <CSanInfrastructureVolume[]>] [-ExcludedVolume <CSanInfrastructureVolume[]>] [-IncludedWildcard <string[]>] [-ExcludedWildcard <string[]>] [-AgentProxy <VBRNASProxyServer[]>] [-AgentVolumeScanType {All | Exclude | Include}] [-AgentIncludedVolume <CSanInfrastructureVolume[]>] [-AgentExcludedVolume <CSanInfrastructureVolume[]>] [-AgentIncludedWildcard <string[]>] [-AgentExcludedWildcard <string[]>] [-SkipRescan] [-Force] [-EnableProxyAutoSelection] [-ProtocolPolicy <VBRStorageProtocolPolicy>] [-AgentEnableProxyAutoSelection] [-AgentProtocolPolicy <VBRStorageProtocolPolicy>] [-EnableVMwareBackup] [-EnableAgentBackup] [<CommonParameters>] |
Detailed Description
This cmdlet modifies settings of HPE Nimble storage systems. When you modify storage system settings, the cmdlet automatically rescans storage systems.
Note |
To modify settings, specify new values for the necessary parameters. The cmdlet will overwrite the previous parameter values with new values. The parameters that you omit will remain unchanged. |
Tip |
You can specify the scope of volumes that you want to rescan with the VBRVolumeScanType parameter. Run the Get-NimbleInfrastructureVolume cmdlet to get an array of volumes from HPE Nimble storage systems. |
Parameters
Parameter | Description | Type | Required | Position | Accept |
---|---|---|---|---|---|
Host | Specifies the storage you want to modify. | Accepts the CNimbleHost object. To get this object, run the Get-NimbleHost cmdlet. | True | Named | True (ByValue, |
Description | Specifies the description of the storage. | String | False | Named | False |
UserName | Specifies the user name that you want to use for authenticating with the storage. | String | False | Named | False |
Password | Specifies the password you want to use for authenticating with the storage. | String | False | Named | False |
Credentials | Specifies the credentials you want to use for authenticating with the storage. | Accepts the CInternalCredentials object. To create this object, run the Get-VBRCredentials cmdlet. | False | Named | False |
MountServer | Specifies the mount server that you want to use to work with this storage. | Accepts the CHost object. To create this object, run the Get-VBRServer cmdlet. | False | Named | False |
EnableVMwareBackup | Enables the VMware backup option. If you provide this parameter, you will be able to use storage snapshots to backup and restore VMware vSphere VMs hosted on storage systems. | SwitchParameter | False | Named | False |
EnableAgentBackup | Enables the Veeam Agent backup option. If you provide this parameter, you will be able to integrate your storage systems with Veeam Agent for Microsoft Windows installed on computers in your infrastructure. | SwitchParameter | False | Named | False |
Proxy | For the EnableVMwareBackup parameter. Specifies the array of proxies you want to use to work with this storage. | String | False | Named | False |
EnableProxyAutoSelection | For the EnableVMwareBackup parameter. Defines that Veeam Backup & Replication will use automatic proxy selection. | SwitchParameter | False | Named | False |
ProtocolPolicy | For the EnableVMwareBackup parameter. Specifies the protocol policy for the storage. | Accepts the VBRStorageProtocolPolicy object. To create this object, run the New-VBRStorageProtocolPolicy cmdlet. | False | Named | False |
VolumeScanType | For the EnableVMwareBackup parameter. Specifies the scope of volumes that you want to rescan. You can use the following options to rescan the volumes:
| VBRVolumeScanType | False | Named | False |
IncludedVolume | For the VolumeScanType parameter with the include option. Specifies an array of storage volumes that you want to rescan. Note: Veeam Backup & Replication will show only rescanned volumes in the backup infrastructure. | Accepts the CSanInfrastructureVolume[] object. To create this object, run the Get-NetAppInfrastructureVolume cmdlet. | False | Named | False |
IncludedWildcard | For the VolumeScanType parameter with the include option. Specifies an array of storage volumes with wildcard characters. Veeam Backup & Replication will rescan only those volumes which names are specified with these wildcard characters. | String | False | Named | False |
ExcludedVolume | For the VolumeScanType parameter with the exclude option. Specifies an array of storage volumes that you do not want to rescan. Note: Veeam Backup & Replication will not show the excluded volumes in the backup infrastructure after the rescan. | Accepts the CSanInfrastructureVolume[] object. To create this object, run the Get-NetAppInfrastructureVolume cmdlet. | False | Named | False |
ExcludedWildcard | For the VolumeScanType parameter with the exclude option. Specifies an array of storage volumes with wildcard characters. Veeam Backup & Replication will not rescan the volumes which names are specified with these wildcard characters. | String | False | Named | False |
AgentProxy | For the EnableAgentBackup parameter. Specifies an array of proxies you want to use with this storage. | Accepts the VBRComputerFileProxyServer object. To create this object, run the Add-VBRComputerFileProxyServer cmdlet. | False | Named | False |
AgentVolumeScanType | For the EnableAgentBackup parameter. Specifies the scope of volumes that you want to rescan. You can use the following options to rescan the volumes:
| VBRVolumeScanType | False | Named | False |
AgentIncludedVolume | For the AgentVolumeScanType parameter with the include option. Specifies an array of storage volumes that you want to rescan. Note: Veeam Backup & Replication will show only rescanned volumes in the backup infrastructure. | Accepts the CSanInfrastructureVolume[] object. To create this object, run the Get-NetAppInfrastructureVolume cmdlet. | False | Named | False |
AgentExcludedVolume | For the AgentVolumeScanType parameter with the exclude option. Specifies an array of storage volumes that you do not want to rescan. Note: Veeam Backup & Replication will not show the excluded volumes in the backup infrastructure after the rescan. | Accepts the CSanInfrastructureVolume[] object. To create this object, run the Get-NetAppInfrastructureVolume cmdlet. | False | Named | False |
AgentIncludedWildcard | For the AgentVolumeScanType parameter with the include option. Specifies an array of storage volumes with wildcard characters. Veeam Backup & Replication will rescan only those volumes which names are specified with these wildcard characters. | String | False | Named | False |
AgentExcludedWildcard | For the AgentVolumeScanType parameter with the exclude option. Specifies an array of storage volumes with wildcard characters. Veeam Backup & Replication will not rescan the volumes which names are specified with these wildcard characters. | String | False | Named | False |
AgentEnableProxyAutoSelection | For the EnableAgentBackup parameter. Defines that Veeam Backup & Replication will use automatic proxy selection. | SwitchParameter | False | Named | False |
AgentProtocolPolicy | For the EnableAgentBackup parameter. Specifies the protocol policy for the storage. | Accepts the VBRStorageProtocolPolicy object. To create this object, run the New-VBRStorageProtocolPolicy cmdlet. | False | Named | False |
SkipRescan | Defines that the cmdlet will not start the storage rescan automatically after you add storage systems to the backup infrastructure. | SwitchParameter | False | Named | False |
Force | Defines that the cmdlet will add an HPE Nimble storage system without showing warnings in the PowerShell console. | SwitchParameter | False | Named | False |
<CommonParameters>
This cmdlet supports Microsoft PowerShell common parameters. For more information on common parameters, see Microsoft Docs.
Examples
Example 1. Specifying Backup Proxy on HPE Nimble Storage System
This example shows how to specify a backup proxy for rescan and backup from Storage Snapshots on a HPE Nimble storage system.
Perform the following steps:
|
Example 2. Excluding HPE Nimble Volumes from Rescan
This example shows how to exclude HPE Nimble volumes from the rescan.
Perform the following steps:
|
Example 3. Rescanning All Volumes Added to HPE Nimble Storage System
This example shows how to rescan all volumes added to an HPE Nimble storage system.
Perform the following steps:
|
Related Commands