Veeam ONE Monitor offers the following types of alarm rules for Veeam Backup & Replication infrastructure objects:

Backup Enterprise Manager

Rule Type

Description

Event-based rule

An alarm is triggered if some Veeam Backup & Replication event is generated for the Veeam Backup Enterprise Manager.

Existing alarm

An alarm is triggered if the state of another selected alarm is changed.

Power or connection state changes

An alarm is triggered if the state of Veeam Backup Enterprise Manager is equal or not equal to the specified value (for example, if connection to the Enterprise Manager is lost).

Backup Server

Rule Type

Description

Event-based rule

An alarm is triggered if some Veeam Backup & Replication event is generated for the backup server.

Disabled job

An alarm is triggered if the time during which a job was disabled has exceeded the specified.

Job duration exceeded the allowed time period

An alarm is triggered if duration of a backup or replication job has exceeded a threshold duration value (specified in minutes).

Existing alarm

An alarm is triggered if the state of another selected alarm is changed.

Power or connection state changes

An alarm is triggered if the state of Veeam Backup server is equal or not equal to the specified value (for example, if connection to the backup server is lost).

Repository

Rule Type

Description

Event-based rule

An alarm is triggered if some Veeam Backup & Replication event is generated for the repository.

Out-of-date state

An alarm is triggered if Veeam Backup & Replication software components installed on the repository server are out of date.

Existing alarm

An alarm is triggered if the state of another selected alarm is changed.

Repository server is running out of free space

An alarm is triggered if free space on the repository is above or below the specified threshold value. You can select to specify the free space threshold as an absolute value (for example, if the storage space should not fall below 10 GB) or a relative value (for example, if the free space should not fall below 15% of total space).

Power or connection state changes

An alarm is triggered if the state of the backup repository is equal or not equal to the specified value (for example, if connection to the repository is lost).

Proxy

Rule Type

Description

Event-based rule

An alarm is triggered if some Veeam Backup & Replication event is generated for the backup proxy.

Out-of-date state

An alarm is triggered if Veeam Backup & Replication software components installed on the proxy server are out of date.

Existing alarm

An alarm is triggered if the state of another selected alarm is changed.

Power or connection state changes

An alarm is triggered if the state of backup proxy is equal or not equal to the specified value (for example, if connection to the proxy server is lost).

WAN Accelerator

Rule Type

Description

Event-based rule

An alarm is triggered if some Veeam Backup & Replication event is generated for the WAN accelerator.

Out-of-date state

An alarm is triggered if Veeam Backup & Replication software components installed on the WAN accelerator server are out of date.

Existing alarm

An alarm is triggered if the state of another selected alarm is changed.

Power or connection state changes

An alarm is triggered if the state of the WAN accelerator is equal or not equal to the specified value (for example, if connection to the WAN accelerator is lost).

Tape Server

Rule Type

Description

Event-based rule

An alarm is triggered if some Veeam Backup & Replication event is generated for the tape server.

Out-of-date state

An alarm is triggered if a version of a component is out of date.

Existing alarm

An alarm is triggered if the state of another selected alarm is changed.

Power or connection state changes

An alarm is triggered if the state of the backup repository is equal or not equal to the specified value (for example, if connection to the server is lost).

Cloud Repository

Rule Type

Description

Event-based rule

An alarm is triggered if some Veeam Backup & Replication event is generated for the cloud repository.

Cloud repository lease expiration

An alarm is triggered if cloud repository lease time will expire in the specified number of days.

Existing alarm

An alarm is triggered if the state of another selected alarm is changed.

Repository server is running out of free space

An alarm is triggered if free space on the repository is above or below the specified threshold value. You can select to specify the free space threshold as an absolute value (for example, if the storage space should not fall below 10 GB) or a relative value (for example, if the free space should not fall below 15% of total space).

Cloud Gateway

Rule Type

Description

Event-based rule

An alarm is triggered if some Veeam Backup & Replication event is generated for the cloud gateway.

Out-of-date state

An alarm is triggered if a version of a component is out of date.

Existing alarm

An alarm is triggered if the state of another selected alarm is changed.

Power or connection state changes

An alarm is triggered if the state of the backup repository is equal or not equal to the specified value (for example, if connection to the cloud gateway is lost).